 3-Line Filters for Converters and Power Electronics
Power line filters for three-phase systems Rated voltage 480/275 and 520/300 V~, 50/60 Hz Rated current 8 to 220 A Construction
s Three-line filter s Metal case s Book size
B84143-G*-R110 B84143-G*-R112
Features
s s s s s s s
High insertion loss Low leakage current Optimized footprint saves space Litz wires on the load side reduce mounting time Low weight Degree of protection: IP 20 1) Design based on EN 133 200, CSA 22.2 No.8 1986 s Optimized for long motor cables and operation under full load s UL 1283 approval for type -R110 , for -R112 UL and CSA approval pending Applications
s Frequency converters for motor drives, e.g.
- elevators - pumps - traction systems - conveyor systems - HVAC systems (heating, ventilation and air conditioning) s Wind farms s Power supplies Terminals
s Line: Safe-to-touch terminal blocks s Load: Litz wires
Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging: Manufacturer's logo, ordering code
1) In accordance with IEC 60529:1989; EN 60529:1991; DIN VDE 0470-1
239 03/01
3-Line Filters for Converters and Power Electronics
Typical circuit diagrams B84143-G8 ... G20-R110/-R112
LINE L1 L2 L3 LOAD L1' L2' L3'
B84143-G*-R110 B84143-G*-R112
SSB1286-Z
B84143-G36 ... G220-R110/-R112
LINE L1 L2 L3 LOAD L1' L2' L3'
SSB1287-8
240 03/01
3-Line Filters for Converters and Power Electronics
Technical data Rated voltage V R Rated current I R Test voltage V P Overload capability Leakage current I leak Climatic category 480/275 V~, 50/60 Hz (type -R110) 520/300 V~, 50/60 Hz (type -R112)
B84143-G*-R110 B84143-G*-R112
Referred to 40 C ambient temperature 1770 V-, 2 s (line/line) 2700 V-, 2 s (lines/case) 1,5 * IR for 3 min per hour or 2,5 * IR for 30 s per hour at 480 V~, 50 Hz 25/100/21 (- 25 C/+ 100 C/21 days damp heat test) in accordance with EN 60068-1
Characteristics and ordering codes IR Terminal cross section load side: line side: litz wires terminal blocks mm2 mm2 8 20 36 50 66 90 120 150 220 4 4 6 16 25 25 50 50 95 1,5 2,5 6,0 10 16 25 35 35 70 Ileak typ. 1) Rtyp Approx. weight Ordering code
A
mA
m 40 10 5,2 2,4 1,8 1,2 1,0 0,7 0,4
kg 1,3 1,3 2,8 3,3 4,4 4,9 7,5 8,0 11,5 B84143-G8-R11* B84143-G20-R11* B84143-G36-R11* B84143-G50-R11* B84143-G66-R11* B84143-G90-R11* B84143-G120-R11* B84143-G150-R11* B84143-G220-R11*
<6 <6 < 16 < 16 < 16 < 16 < 16 < 16 < 16
Compilation of ordering code Replace the asterisk * by the code number for the required version: 0 = 480 / 275 V 2 = 520 / 300 V
1) At rated operation
241 03/01
3-Line Filters for Converters and Power Electronics
Dimensional drawings B84143-G8-R11*, B84143-G20-R11*
50 200 30010
Litz wire Litze
B84143-G*-R110 B84143-G*-R112
Terminal Anschlussblocks 4 mm 2 klemmen 4 mm2
31 15
L3' L2' L1' PE
Wire end ferrule Aderendhulse Litz wire markings Litzenbezeichnung
80
40
0,5
PE M6 x 25
230 2150,5
6,5
L1 L2 L3
1
Marking LINE LOAD
250,3 46
SSB1291-1
B84143-G36-R11*
60
Terminal Anschlussblocks 6 mm 2 klemmen 6mm2
250
40010
Litz wire Litze
L3' L2' L1'
150
75
60 30
0,5
PE
1
Wire end ferrule Aderendhulse Litz wire markings Litzenbezeichnung
PE M6 x 25
280 2650,5
L1 L2 L3
6,5
Marking LINE LOAD
350,3
56
SSB1292-9
242 03/01
3-Line Filters for Converters and Power Electronics
B84143-G50-R11*
60
Terminal Anschlussblocks 16 mm 2 klemmen16 mm2
B84143-G*-R110 B84143-G*-R112
300
50010
Litz wire Litze
L3' L2'
150
75
L1'
52
30
0,5
1
PE
Wire end ferrule Aderendhulse Litz wire markings Litzenbezeichnung
PE M6 x 25 330 3150,5 L1 L2 L3
Marking LINE LOAD
350,3 56
6,5
SSB1293-H
B84143-G66-R11*, B84143-G90-R11*
80
Terminal Anschlussblocks 25 mm 2 klemmen25 mm2
300
50010
Litz wire Litze
L3'
150
L2'
75
L1'
52 30
0,5
PE
Wire end ferrule Aderendhulse Litz wire markings Litzenbezeichnung
PE M10 x 35
L2 L3
Marking LINE LOAD
550,3
L1
6,5 76
330 3150,5
1
SSB1294-Q
243 03/01
3-Line Filters for Converters and Power Electronics
B84143-G120-R11*, B84143-G150-R11*
90
Terminal Anschlussblocks klemmen 50 mm 2 2 50 mm
B84143-G*-R110 B84143-G*-R112
350
50010
Litz wire Litze
L3'
200
L2'
100
40
78
L1' PE
0,5
PE M10 x 35
1
Wire end ferrule Aderendhulse Litzenbezeichnung Litz wire markings
380 3650,5
L2 L3
Marking LINE LOAD
650,3
L1
6,5 86
SSB1295-Y
B84143-G220-R11*
Terminal blocks 95 mm 2 Anschlussklemmen95 mm2 Litz wire Litze Wire end ferrule Aderendhulse
110
400
50010
L3'
220
L2' L1' PE
1
Litz wire markings Litzenbezeichnung
110
79
PE M10 x 35
30
430 4150,5
0,5
L1 L2 L3
6,5
Marking LINE LOAD
850,3
106
SSB1348-T
244 03/01
3-Line Filters for Converters and Power Electronics
Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-G8-R11*
120
SSB1288-G
B84143-G*-R110 B84143-G*-R112
B84143-G20-R11*
120
SSB1289-P
e
dB 100
e
dB 100
80
80
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
0 10 4
10 5
10 6
10 7
Hz 10 8 f
B84143-G36 ... G220-R11*
120
SSB1290-S
e
dB 100
80
60
40
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
245 03/01
Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 Munchen, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfaltigung, Veroffentlichung, Verbreitung und Verwertung dieser Broschure und ihres Inhalts ohne ausdruckliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschure werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen fur Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschure ersetzt die vorige Ausgabe. Fragen uber Technik, Preise und Liefermoglichkeiten richten Sie bitte an den Ihnen nachstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente konnen aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskunfte daruber bitten wir unter Angabe des betreffenden Typs ebenfalls uber die zustandige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS' prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices.
1


▲Up To Search▲   

 
Price & Availability of B84143-G90-R11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X